Products » Detector modules » Portable » Radscanner PRD, SPRD & SPRDN

Standard Specifications

Radscanner PRD

Radscanner SPRD

Radscanner SPRDN

MEANT FOR DEVICE TYPE
Handheld personal radiation detector
Handheld personal radiation detector
Handheld personal radiation detector
RADIATION TYPE
Gamma
Gamma
Gamma, neutron
SENSOR TYPE
SEM scintillator
SEM scintillator
SEM scintillator
COUNT RATE (CS-137)
130 cps/µSv/h
130 cps/µSv/h
130 cps/µSv/h
GAMMA ENERGY RANGE
40 keV - 1,3 MeV
40 keV - 1,3 MeV
40 keV - 1,3 MeV
SPECTRUM OF GAMMA ENERGY
No
Yes
Yes
GAMMA RESOLUTION
< 10 %
< 10 %
GAMMA MEASUREMENT LIMIT
max. 500 µSv/h
max. 500 µSv/h
max. 500 µSv/h
NEUTRON COUNTING
No
No
Yes
NEUTRON SENSITIVITY
Contact for details
MODULE SIZE
< 90 cm³
< 90 cm³
< 120 cm³
WEIGHT
60 g
60 g
80 g
POWER REQUIREMENT
< 140 mW
< 140 mW
< 200 mW
OPERATING TEMPERATURE
-20 - +50 celcius
-20 - +50 celcius
-20 - +50 celcius
COMPATIBILITY
EMC, EC, RoHS
EMC, EC, RoHS
EMC, EC, RoHS
PERFORMANCE STANDARDS AS IN
IEC62401
IEC62618
IEC62401, IEC62618

Radscanner PRD

MEANT FOR DEVICE TYPE
Handheld personal radiation detector

RADIATION TYPE
Gamma

SENSOR TYPE
SEM scintillator

COUNT RATE (CS-137)
130 cps/µSv/h

GAMMA ENERGY RANGE
40 keV - 1,3 MeV

SPECTRUM OF GAMMA ENERGY
No

GAMMA RESOLUTION
-

GAMMA MEASUREMENT LIMIT
max. 500 µSv/h

NEUTRON COUNTING
No

NEUTRON SENSITIVITY
-

MODULE SIZE
< 90 cm³

WEIGHT
60 g

POWER REQUIREMENT
< 140 mW

OPERATING TEMPERATURE
-20 - +50 celcius

COMPATIBILITY
EMC, EC, RoHS

PERFORMANCE STANDARDS AS IN
IEC62401

Radscanner SPRD

MEANT FOR DEVICE TYPE
Handheld personal radiation detector

RADIATION TYPE
Gamma

SENSOR TYPE
SEM scintillator

COUNT RATE (CS-137)
130 cps/µSv/h

GAMMA ENERGY RANGE
40 keV - 1,3 MeV

SPECTRUM OF GAMMA ENERGY
Yes

GAMMA RESOLUTION
< 10 %

GAMMA MEASUREMENT LIMIT
max. 500 µSv/h

NEUTRON COUNTING
No

NEUTRON SENSITIVITY
-

MODULE SIZE
< 90 cm³

WEIGHT
60 g

POWER REQUIREMENT
< 140 mW

OPERATING TEMPERATURE
-20 - +50 celcius

COMPATIBILITY
EMC, EC, RoHS

PERFORMANCE STANDARDS AS IN
IEC62618

Radscanner SPRDN

MEANT FOR DEVICE TYPE
Handheld personal radiation detector

RADIATION TYPE
Gamma, neutron

SENSOR TYPE
SEM scintillator

COUNT RATE (CS-137)
130 cps/µSv/h

GAMMA ENERGY RANGE
40 keV - 1,3 MeV

SPECTRUM OF GAMMA ENERGY
Yes

GAMMA RESOLUTION
< 10 %

GAMMA MEASUREMENT LIMIT
max. 500 µSv/h

NEUTRON COUNTING
Yes

NEUTRON SENSITIVITY
1,2 cps/nv

MODULE SIZE
< 120 cm³

WEIGHT
80 g

POWER REQUIREMENT
< 200 mW

OPERATING TEMPERATURE
-20 - +50 celcius

COMPATIBILITY
EMC, EC, RoHS

PERFORMANCE STANDARDS AS IN
IEC62401, IEC62618